Your current location: Home -> Technical Support -> Technical Services
Riso ComColorError Code S35:Ink supply unit error
Release time:2023.03.06 Author:admin Views:966

Riso ComColor Machines Errors Trouble-Shooting!

    Suitable for ComColor 3010R/3050R/7050R/9050R/ 3150R/7150R/9150R

    ComColor 3050/7050/9050/3150/7150/9150


Error Codes Display and Details

    S35: Ink supply unit error

    S35-2055, S35-2069, S35-2070, S35-2071, S35-2072, S35-2074, S35-2075, S35-2076

TypeS35:Ink supply unit error
Display!!System Error!!
Turn the powder SW OFF then ON.

If recovery has failed, call service
Corrective ActionTurn OFF the printer. (Turn OFF the printer through sub power key.)
PointDescription
2055
The bellows sensor was activated during ink circulation.
20691Pressurized ink tank ink sensor K was not activated even once as the printer detected no black ink three times. 
20692Pressurized ink tank ink sensor K remained OFF for more than a particular number of cycles despite circulation (printing pressure). 
20701Pressurized ink tank ink sensor C was not activated even once as the printer detected no cyan ink three times. 
20702Pressurized ink tank ink sensor C remained OFF for more than a particular number of cycles, despite circulation (printing pressure).
20711Pressurized ink tank ink sensor M was not activated even once as the printer detected no magenta ink three times.
20712Pressurized ink tank ink sensor M remained OFF for more than a particular number of cycles, despite circulation (printing pressure).
20721Pressurized ink tank ink sensor Y was not activated even once as the printer detected no yellow ink three times.
20722Pressurized ink tank ink sensor Y remained OFF for more than a particular number of cycles, despite circulation (printing pressure).
20741Negative pressure ink tank ink sensor C remained OFF, despite circulation (printing pressure).
20742Negative pressure ink tank ink sensor C remained ON, despite circulation (printing pressure).
20751Negative pressure ink tank ink sensor M remained OFF, despite circulation (printing pressure).
20752Negative pressure ink tank ink sensor M remained ON, despite circulation (printing pressure).
20761Negative pressure ink tank ink sensor Y remained OFF, despite circulation (printing pressure).
20762Negative pressure ink tank ink sensor Y remained ON, despite circulation (printing pressure).


Contact Us

Tel: +86-592 6896238
Fax:+86-592-6896237
Mob./whatsapp: +86 13860165915 
E-mail:info@kreyoly.com 
http://www.kreyoly.com
Add: 604-9,No. 22, Guanri Road, Software Part II, Xiamen Torch Development Zone For High Technology Industries,361008,China